MIL-DTL-83526C
TABLE II. Qualification inspection Continued.
Part applicability 1/
Inspection
Requirement
Test
paragraph
paragraph
Connector Backshell Accessories
Group IV 2/
(2 sample units)
Terminus cleaning
X
X
Electromagnetic effects
X
X
X
Coupling force
X
X
X
Coupling torques
X
X
X
Electromagnetic shielding
X
X
Mating durability 3/
X
X
Humidity
X
X
Salt spray
X
X
X
Sand and dust
X
X
X
Impact
X
X
X
Flammability
X
X
Group V 2/
(2 sample units)
Appendix A
Intermateability and interoperability
X
X
X
1/ X: Indicates that this test applies.
2/ Sample units: Number indicated means that the number of connectors, backshells or accessories
that shall be tested, for example "2 sample units" means 2 connectors and 2 accessories shall be
tested when an "X" appears in the part applicability column under "connector" and "accessories".
3/ After every 100 cycles.
TABLE III. Sampling plans
Lot size
Samples
18
All
9 50
5
51 90
7
91 150
11
151 280
13
281 500
16
501 1200
19
1201 3200
23
3201 10,000
29
4.7.1.2.2 Rejected lots. If an inspection lot is rejected, the lot shall be screened for that particular
defect and defects removed. A new sample shall be selected from table III using the sample size of the
next higher lot size. If one or more defects are found in the second sample, the lot shall be rejected and
not supplied to this specification.
17
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business