MIL-DTL-83526C
TIA/EIA-455-1
-
Cable Flexing for Fiber Optic Interconnection Devices
* TIA/EIA-455-2
-
Optic Devices, Fiber, Impact Test Measurements for
* TIA/EIA-455-4
-
Fiber Optic Component Temperature Life
* TIA/EIA-455-5
Humidity Test Procedure for Fiber Optic Components and Cable
-
TIA/EIA-455-11
Vibration Test Procedure for Fiber Optic Components
-
* TIA/EIA-455-16
Salt Spray Test Procedure for Fiber Optic Components
-
* TIA/EIA-455-32
-
Fiber Optic Circuit Discontinuities
* TIA/EIA-455-34
-
Interconnection Device Insertion Loss Test
* TIA/EIA-455-35
-
Fiber Optic Component Dust (Fine Sand) Test
TIA/EIA-455-71
-
Procedure to Measure Temperature-Shock Effects on Fiber Optic
Components
* EIA-557
-
Statistical Process Control Systems
* TIA/EIA-604
-
Fiber Optic Connector Intermateability Standards (FOCIS)
* Adopted by DoD
(Application for copies of publications should be addressed to Electronic Industries Association,
Engineering Dept. /Telecommunications Industry Association, Standards and Technology Dept., 2500
INSTITUTE OF ELECTRICAL AND ELECTRONIC ENGINEERS (IEEE)
* IEEE-299
-
Measuring the Effectiveness of Electromagnetic Shielding Enclosures
* Adopted by DoD
(Application for copies should be addressed to the Institute of Electrical and Electronic Engineers, 445
Hoes Lane, Picataway, New Jersey 08855-1331, https://shop.ieee.org/ieeestore/).
2.4 Order of precedence. In the event of a conflict between the text of this document and the
references cited herein (except for related specification sheets), the text of this document takes
precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a
specific exemption has been obtained.
3. REQUIREMENTS
3.1 Specification sheets. The individual item requirements shall be as specified herein and in
accordance with the applicable specification sheets. In the event of any conflict between the
requirements of this specification and the specification sheet, the latter shall govern.
3.2 Qualification. Fiber optic connectors and accessories furnished under this specification shall be
products, which are authorized by the qualifying activity for listing on the applicable qualified products list
3.2.1 QPL system. The manufacturer shall establish and maintain a QPL system for parts covered by
this specification. Requirements for this system are specified in MIL-STD-790.
3.2.2 SPC system. As a part of the overall MIL-STD 790 QPL system, the manufacturer shall establish
a SPC system that meets the requirements of EIA-557