MIL-PRF-29504B
3.8 Workmanship. Termini shall be processed in such a manner as to be
uniform in quality and shall be free from foreign material and burrs or sharp
corners that might interfere with the termination process, damage the
connector or affect mating of the termini.
4.
VERIFICATION
4.1 Verification program. Requirements for the verification program shall
be as required by the qualifying activity (see 6.3.3).
4.1.2 Assembly plants. Assembly plants shall be listed on, or approved for
listing on, the applicable qualified products list. The qualified terminus
manufacturer shall certify that the assembly plant is approved for the
distribution of the manufacturer's parts. The assembly plant shall use only
piece parts supplied by the qualified terminus manufacturer. No testing other
than visual examination is required of certified piece parts obtained from the
qualified terminus manufacturer, except when there is cause for rejection.
All assemblies produced at the assembly plant shall be subjected to
examination of the product to assure that the assembly process conforms with
that established at the qualified manufacturing plant. Quality control
requirements, including Government inspection surveillance, shall be the same
as required for the qualified termini manufacturer.
4.2 Test equipment and inspection facilities. Requirements for test
equipment and inspection facilities shall be as required by the qualifying
activity (see 6.3.4).
4.3 Classification of inspections.
The inspection requirements specified
herein are classified as follows:
a. Materials Inspection (see 4.5).
b. Qualification inspection (see 4.6).
c. Conformance inspection (see 4.7).
4.4 Inspection conditions. Unless otherwise specified, all inspections
shall be performed in accordance with the standard test conditions specified
in TIA/EIA-455 or as specified herein.
4.5 Materials inspection. Materials inspection shall consist of
certification supported by verification that materials used in fabricating the
delivered fiber optic termini are in accordance with the requirements of 3.3
and as specified (see 3.1).
4.6 Qualification inspection. Qualification inspection shall be performed
at a laboratory acceptable to the Government, on sample units produced with
equipment and procedures normally used in production (see 3.2).