MIL-PRF-29504B
(Non-Government standards and other publications are normally available from
the organizations which prepare or which distribute the documents. These
documents also may be available in or through libraries or other informational
services.)
2.4 Order of precedence. In the event of a conflict between the text of
this document and the references cited herein (except for related associated
specifications or specification sheets), the text of this document takes
precedence. Nothing in this document, however, supersedes applicable laws and
regulations unless a specific exemption has been obtained.
3.
REQUIREMENTS
3.1 Specification sheets. The individual item requirements shall be as
specified herein and in accordance with the applicable specification sheet.
In the event of any conflict between the requirements of this specification
and the specification sheet, the latter shall govern.
3.2 Qualification. Termini furnished under this specification shall be
products that are authorized by the qualifying activity for listing on the
applicable qualified products list before contract award (see 4.6 and 6.3).
The provisions of 4.6.4 for retention of qualification are included in this
requirement.
3.3 Materials. Materials shall be as specified herein and in the
applicable specification sheet. In all cases, materials selected for use
shall meet all qualification requirements as specified, and be of a type and
quality to assure physical, chemical, and optical compatibility with the
requirements of this specification. All materials used shall be nontoxic (see
3.3.1), nonnutrient to fungus (see 3.3.5) and manufactured to good workmanship
quality (see 3.8).
3.3.1 Toxic and hazardous products and formulations. The products used in
the terminus construction shall not give off toxic or explosive fumes when
exposed to flame. Materials used shall have no adverse effect on the health
of personnel when used for the intended purpose.
3.3.2 Metals. Metals which are inherently susceptible to corrosion are
prohibited. In addition, unless otherwise specified (see 3.1), metals which
are inherently magnetic are prohibited.
3.3.3 Dissimilar metals. The use of dissimilar metals in intimate contact
should be avoided. When dissimilar metals are used in intimate contact with
each other, protection against electrolysis and corrosion shall be provided.
3.3.4 Nonmetallic materials. Nonmetallic materials used in termini shall
not be degraded by the use of solvents, adhesives or cleaning agents, nor be
degraded at the specified environmental conditions.
3.3.4.1 Adhesives. Adhesives are not precluded from use in the
construction of termini to this specification. The types of adhesives which
may be used are defined in the associated specification sheet (see 3.1).
3.3.4.2 Sealing compounds. Sealing compounds which may flow at the maximum
upper storage temperature specified herein, or may crack at the minimum lower
storage temperature specified herein shall not be used.
3
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business