3.6.8 Environmental/mechanical. When tested in accordance with 4.9.10,
termini shall not exhibit visual evidence of dimensional change, opening of
seals, cracking or crazing of components or finishes, identification marking
impairment, fusion or seizure of mating parts, breakage of the fiber within
the terminus, or other effects detrimental to terminus operation. The termini
shall meet the optical requirements of 3.5.3 and 3.5.4 as specified in the
associated specification sheet (see 3.1).
3.6.9 Terminus insertion and removal forces. When tested in accordance
with 4.9.11, the terminus insertion force and the force required to remove
unlocked termini shall be not greater than 22 pounds (98 N).
3.6.10 Fiber pull out force. When tested in accordance with 4.9.12, the
minimum fiber to terminus pullout strength shall be 3.1 lbs (14 N). The
terminus shall meet the optical requirements of 3.5.4 during and after the
test.
3.6.11 Cable pull out force. When tested in accordance with 4.9.13, the
minimum cable to terminus pullout strength shall be 22 pounds (98 N). The
terminus shall show no evidence of cable jacket damage, crimp sleeve failure,
distortion from bending of terminus parts or cable disengagement from the
terminus. The terminus shall meet the optical requirements of 3.5.4 during
and after the test.
3.6.12 Mating durability. When tested in a qualification connector (see
3.1) in accordance with 4.9.14 for 500 mating cycles, the termini shall show
no evidence of defects which may be detrimental to their mechanical or optical
performance. The terminus shall meet the requirements of 3.5.4 during and
after the test.
3.6.13 Maintenance aging. When tested in a qualification connector (see
3.1) in accordance with 4.9.15 for 10 insertion/removal cycles, termini shall
show no visible evidence of wear or deformation which may degrade their
ability to perform as specified. The requirements of 3.6.9 shall be met
during the test.
3.7. Marking. Removable termini shall be permanently and legibly marked
with the manufacturer's symbol or trademark and the TICC bands (see figure 1).
Unless otherwise specified (see 3.1), markings shall remain legible after
tests. Flaking of the color bands in the crimp indenter area is acceptable
provided the color of the bands is still identifiable. It shall be acceptable
to laser mark the TICC band code numbers on the termini.
3.7.1 Manufacturer's symbol or trademark. When specified (see 3.1), the
manufacturer's symbol or trademark shall be marked as shown on figure 1,
unless otherwise specified (see 3.1), or on the fiber barrel side of the
shoulder. The manufacturer shall list the symbol or trademark with SAE in
accordance with AIR1351.
3.7.2 TICC bands. Each digit of the TICC shall be designated on the
terminus by a color band in accordance with the following:
0
-
Black
4
-
Yellow
7
-
Violet
1
-
Brown
5
-
Green
8
-
Gray
2
-
Red
6
-
Blue
9
-
White
3
-
Orange