MIL-PRF-29504/15A
To qualify or requalify termini to this specification sheet, all requirements
of MIL-PRF-28876 shall be met using the qualifying terminus in a connector
qualified to MIL-PRF-28876.
Qualification connector: The qualification connector for this terminus shall
be a qualified MIL-PRF-28876 connector.
Test specimens: Test specimens shall be constructed using a 62.5/125 micron
optical fiber within a single fiber cable with an outer diameter not greater
than 2.4 mm.
Part or identifying number (PIN):
See table I and 6.6 of MIL-PRF-29504.
M29504/15
-XXXX
X
|
|
|
Basic specification
TICC Code
Crimp sleeve
and specification
(see table I)
(optional)
sheet
Qualification by similarity: Manufacturers who are qualified under this
specification sheet for single-mode termini, and whose multimode termini pass
the size, insertion loss, and shock inspections specified herein, are
qualified under this specification sheet for multimode termini sizes. Testing
is to be performed using four mated pair. This qualification by similarity is
valid if the only difference between the previously qualified single-mode
termini and the multimode termini is a change in the terminus ferrule
dimensions.
Manufacturers who are qualified under this specification sheet for a long
terminus, and whose short termini pass the size inspections specified herein,
are qualified under this specification sheet for short termini. Testing is to
be performed on four terminus samples. This qualification by similarity is
valid if the only difference between the previously qualified long termini and
the short termini is a change in overall terminus length.
Manufacturers who are qualified under this specification sheet for multimode
termini, and whose single-mode termini pass the size, identification marking,
workmanship, insertion loss, return loss, cable pull out force, mating
durability, shock, temperature cycling, temperature life, and flammability
inspections specified herein, are qualified under this specification sheet for
single-mode termini. Testing is to be performed using four mated pair. This
qualification by similarity is valid if the only difference between the
previously qualified multimode termini and the single-mode termini is a change
in the terminus ferrule dimensions.
Usage: Termini compliant with this specification sheet may be used in
connectors other than MIL-PRF-28876 at the discretion of the acquiring
activity.