MIL-PRF-29504/1B
REQUIREMENTS:
Design and construction:
Dimensions and configuration:
See figures 1 and 2 and table I.
Weight:
1 gram maximum.
Adhesives:
Use MIL-PRF-24792 or as approved by the qualifying activity.
Tools:
See table II.
Mating termini:
MIL-PRF-29504/2 and MIL-PRF-29504/13.
Crimp sleeve: (for 2.4 mm maximum diameter cable) to be supplied with
terminus when specified in the PIN.
Circular runout:
Not greater than 2.5 micrometers.
Optical performance:
Insertion loss: The initial insertion loss of a mated pin and socket shall
be not greater than 1.5 dB. The maximum insertion loss of a mated pin and
socket at any time during testing shall be not greater than 2.0 dB.
Environmental/mechanical: Termini shall be tested to the following MIL-PRF-
28876 environmental and mechanical requirements. Change in optical
transmittance and optical discontinuity requirements shall be as specified
in MIL-PRF-28876.
Impact
Vibration
Shock
Thermal shock
Temperature/humidity cycling
Temperature cycling
Temperature life
Flammability
Ozone exposure
To qualify or requalify termini to this specification sheet, all requirements
of MIL-PRF-28876 shall be met using the qualifying terminus in a connector
qualified to MIL-PRF-28876.
Qualification connector: The qualification connector for this terminus shall
be a qualified MIL-PRF-28876 connector.
Test specimens: Test specimens shall be constructed using a 62.5/125 micron
optical fiber within a single fiber cable with an outer diameter not greater
than 2.4 mm.