MIL-C-83522/1F
Optical requirements:
Number of optical termini: One.
Coupling loss (attenuation): 3 dB maximum per mated pair.
Weight: 6 grams maximum.
Polarization: Not applicable.
Safety wire holes: Optional.
Force to engage and disengage:
Longitudinal force: 12 pounds maximum.
Torque: 4 inch-pounds maximum.
Coupling proof torque: 5 inch-pounds minimum.
Coupling mechanism retention force: 60 pounds minimum.
Ozone exposure: Not applicable.
Durability: 200 cycles, 1 dB maximum change.
Low temperature: 1 dB change.
Plug accessories: Each plug shall be supplied with a minimum of one crimp ferrule as needed (see figure 1); two
alignment sleeves (see figure 2); one protective cable-end cap; one 1.5 inch length of heat-shrink tubing or one
rubber boot; and one set of assembly instructions. The assembly instructions shall include a listing of the epoxies
specified in this specification sheet and a cleaning procedure statement as follows:
Cleaning procedures: Dampen lens tissue (paper wipes or cotton swab) with a small amount of isopropyl alcohol or
water. Gently wipe the face of the connector, removing any debris, particularly around the optical fiber, using clean
lens tissue (paper wipes, cotton swab). Dry face of connector by blowing with dry air.
NOTE: The plug mates with MIL-C-83522/4 receptacle; MIL-C-83522/5 receptacle, MIL-C-83522/7 receptacle;
MIL-C-83522/8 receptacle; or a MIL-C-83522/3 adapter mated with another MIL-C-83522/1 plug. Connection to
any other type plug may result in excessive coupling loss.
Referenced documents: In addition to MIL-C-83522, this document references the following:
MIL-PRF-49291
MIL-C-83522/7
ASTM-B36/B36M
ASTM-B197/B197M
MIL-C-83522/3
MIL-C-83522/8
ASTM-B122/B122M
SAE-AMS-QQ-S-763
MIL-C-83522/4
MIL-PRF-85045
ASTM-B194
MIL-C-83522/5
ASTM-B16/B16M
ASTM-B196/B196M
5