MIL-C-83522/4F
REQUIREMENTS:
Metals: The receptacle housing and other metal components shall be of corrosion resistant steel in accordance
with SAE-AMS-QQ-S-763, class 303 or nickel plated brass in accordance with ASTM-B36/B36M alloys C23000,
C24000, C26000, or C26800 or ASTM-B16/B16M or ASTM-B122/B122M alloys C377000, C46400, C48200, or
C48500.
Weight: 5 grams maximum.
Safety wire holes: Not applicable.
Force to engage and disengage:
Longitudinal force: 12 pounds maximum.
Torque: 4 inch-pounds maximum.
Coupling proof torque: Not applicable.
Coupling mechanism retention force: Not applicable.
Ozone exposure: Not applicable.
Receptacle accessories: 2 screws, 1 dustcover, TO can alignment sleeve(s), and one dust cover.
NOTES: The receptacle mates with MIL-C-83522/1 plug and MIL-C-83522/2 plug.
The receptacle accepts TO can sizes 18, 46, and 52.
Referenced documents: In addition to MIL-C-83522, this document references the following:
MIL-C-83522/1
ASTM-B16/B16M
ASTM-B122/B122M
MIL-C-83522/2
ASTM-B36/B36M
SAE-AMS-QQ-S-763
Marginal notations are not used in this revision to identify changes with respect to the previous issue due to the
extent of the changes.
Custodians:
Preparing activity:
Army - CR
DLA - CC
Navy - SH
Air Force - 11
(Project 6060-2006-014)
DLA - CC
Review activities:
Navy - AS
Air Force 02, 03, 19, 33, 93, 99
DIA - DI
NASA - NA
NOTE: The activities listed above were interested in this document as of the date of this document. Since
organizations and responsibilities can change, you should verify the currency of the information above using the
ASSIST Online database at https://assist.daps.dla.mil/.
3
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business